Install InView Marquee Message Display 1-21
7. Insert the wires into the appropriate terminal connection and
tighten the screw to 0.79 Nm (7 lb-in).
The terminal block is UL rated for wire ranges of 14 to 8 AWG.
8. Remove the necessary hole plugs before connecting the
communications cables.
9. Connect the incoming communication wires per the tables
below.
TB1 is used for P9x pass-through. TB2 is used for supplying
power to the optional InView Legacy Communication board kit.
ATTENTION
Use shielded Ethernet cable. Shielded Ethernet
cable is required to maintain noise immunity.
The 2706-PCable1 is used for downloading
messages only and must be removed after
downloading is complete.
Power connection
LINE 1
GR
OUND
LINE 2 OR
NEUTRAL
LINE 1
GR
OUND
LINE 2 OR
NEUTRAL
208 - 240 VAC INPUT
Neutral
(Line 2): WHITE
Line
(Hot) BLACK
Ground
GREEN w/ Yellow
RJ-12
TB3
TB2
TB1
Ethernet
Communication
Openings
TB1 RS-485
Pin
Pin Name
Pin
Pin Name
1.
GND
4.
CH A
2.
SHLD
5.
CH B
3.
COMM
6.
TERM