4. Feed electrical cable through 12.7 mm (0.5 in.) water-tight
conduit, the outside end of the connector (supplied), the
electrical opening in the sign case, and then through the inside
end of the connector.
5. Screw the inside and outside ends of the connector together
until water-tight.
6. Strip the electrical wires back 6.35 mm (0.25 in.).
Half-turn latches on an 2706-P94C sign
Front view,
closed
Front view, open
Power connection
terminal block
Electrical
opening
Communication
opening
TIP
Use either of the two holes nearest the power
connection terminal block.
Front view
Sign case,
inside
Conduit
Connector,
outside end
Connector nut, with teeth
facing the sign case
Rubber gasket