Set Serial Address

This command will change a serial address for a display.

Text Position Placement

Allen-Bradley uses the 2706-P42, 2706-P44, and 2706-P72 series
displays with InView industrial protocol. The displays can be single
line, two-line or 3-line. Displaying of messages using protocol is
slightly different based on which display is being used.

Below are some rules for the 2706-P44 and 2706-P72 display. The
2706-P42 display ignores the display position and show (display) the
text.

Special Function Command to Set Serial Address

<SOH>

Type Code

Display Address

Description

ASCII

Hex

Description

ASCII

Hex

Description

ASCII

Hex

Start of Header

^A

01

All displays

Z

5A

Display Address

01-FF

3031-4646

Special Function Command to Set Serial Address Continued

<STX>

Command Code

Command

Function

Description

ASCII

Hex

Description

ASCII

Hex

Description

ASCII

Hex

Start of Text

^B

02

Write Special Function

E

45

Set address

7

37

Special Function Command to Set Serial Address Continued

Command Code (Continued)

<EOT>

Serial address

ASCII

Hex

Description

ASCII

Hex

New serial address

01-FE

3031-4645