2-14 InView System Connectivity

6. Enter 3001 for the Port if using a 2706-PENET1 module.

7. Enter the MAC Address of the module under the heading Assign

IP Address.

The MAC Address is found on the module itself.

8. Click the Setup button located in the section titled Assign IP

Address once the desired IP Address, Port, and MAC Address
have been entered.

If the IP Address is already in use, an error message window
appears.

As the message instructs, you need to either turn the display on
or power cycle the display if it is already turned on. Upon
successfully assigning an IP Address the following window
appears.

TIP

The 2706-P9x display does not use MAC Address. IP
Address changes must be done serially.

TIP

If the Invalid IP Address window appears, click
OK, choose a different desired IP Address, and
click the Setup button again. Once a valid IP
Address is entered, the following window should
appear saying it is ready to assign an IP address.