Set day and date in broadcast mode -23, Set day and date in broadcast mode – Rockwell Automation 2706-P42_P43_P44_P72_P74_P92_P94 InView Marquee Message Display User Manual User Manual
Page 89

Publication 2706-UM016D-EN-P - March 2006
InView Protocol 4-23
Transmission for Setting Time with 24 Hour Format
Response: NONE
300 ms pause
2. Clear the message queue.
This transmission is used to remove time that was just loaded
into the message queue.
Transmission:
Transmission for Clearing the Message Queue
Response: NONE
Set Day and Date in Broadcast Mode
This command is used to set the date in all displays. This is primarily
done using the automation software to synchronize the date in the
displays with the computer. This requires three separate transmissions.
First, set the date. Second, set the day of week. Third, clear the queue.
The following is an example of setting the day and date to Thursday,
January 4, 2001.
1. Set the date.
Transmission:
ADDR
Beginning
of Frame
FUNC
H.O.
ADDR
L.O.
ADDR
DATA
EOF Ready to
rec. resp
:
FF
01
00
64
^AZ00^BE 1035^C^BE’M^C^D
CR
LF
TIP
See section InView Display Communication Protocol
Functions and Descriptions on for further
explanation of the InView sign protocol being used.
Beginning
of Frame
ADDR
FUNC
H.O.
ADDR
L.O.
ADDR
DATA
LRC
Error
EOF
Ready to
rec. resp
:
FF
06
00
65
FFFF
98
CR
LF