Publication 2706-UM016D-EN-P - March 2006
1-4 Install InView Marquee Message Display
5. Insert the serial wires through the right conduit hole on either
the top or the bottom of the sign.
6. Connect the incoming serial wires.
TIP
TB1 can be used for incoming serial connection for
RS-232 or RS-485.
H
N
Hot (Line 1)
Ground
Neutral
(Line 2)
Neutral
(Line 2):
WHITE
Line
(Hot)
BLACK
Ground
GREEN
w/
Yellow
100 to 240V ac
@ 50/60 Hz
Insert the
serial wires
into one of these
conduit holes.
TB1
TB1 - Full
Pin
Pin Name
Pin
Pin Name
1.
GND
5.
RS-485(+)
2.
+5V
6.
RS-485(-)
3.
RS-232 TX
7.
NC
4.
RS-232 RX
8.
SHIELD