4-22 InView Protocol

Transmission for Setting Time with AM/PM Format

Response: NONE

300 ms pause

2. Clear the message queue.

This transmission is used to remove the time that was just
loaded into the message queue.

Transmission:

Transmission for Clearing the Message Queue

Response: NONE

Set Time in Broadcast Mode with 24 Hour Format

This command is used to set the time and the format for the time in all
displays. This is primarily done using the automation software to
synchronize the time in the displays with the computer. This requires
two separate transmissions. First, set the time and format for the time.
Second, clear the queue. The following is an example of setting the
time to 1035 and the format for the time to be 24 hour (military)
format.

1. Set the time and time format.

Transmission:

ADDR

Beginning of
Frame

FUNC

H.O.

ADDR

L.O.

ADDR

DATA

EOF

Ready to rec.
resp

:

FF

01

00

64

^AZ00^BE 1034^C^BE’S^C^D

CR

LF

TIP

See section InView Display Communication Protocol
Functions and Descriptions on
for further
explanation of the InView sign protocol being used.

Beginning of
Frame

ADDR

FUNC

H.O.

ADDR

L.O.

ADDR

DATA

LRC

Error

EOF Ready

to rec.
resp

:

FF

06

00

65

FFFF

98

CR

LF