Page 109

Advertising
background image

Publication 2706-UM016D-EN-P - March 2006

InView Protocol 4-43

InView Message Format Continued

Mode

Speed

Justification

Description

ASCII

Hex

Description

ASCII

Hex

Description

ASCII

Hex

Rotate left

a

61

(No Hold)

^I

09

Left

^^1

1E31

Hold

b

62

(1 Sec.)

^U

15

Center

^^0

1E30

(2 Sec.)

^V

16

(3 Sec.)

^W

17

(4 Sec.)

^X

18

(5 Sec.)

^Y

19

InView Message Format Continued

Message Attributes

Character Font

Character Color

Character Width/Height

Description

ASCII

Hex

Description

ASCII

Hex

Description

ASCII

Hex

5 High Standard

^Z1

1A31

Red

^\1

1C31

Standard

^Q^]10

111D3130

7 High Standard

^Z3

1A33

Green

^\2

1C32

Wide

^R^]10

121D3130

7 High Fancy

^Z5

1A35

Yellow

^\3

1C33

Dble Wide

^Q^]11

111D3131

10 High Standard

^Z6

1A36

Double High

^Q^]21

111D3231

16 High Fancy (Full Height)

^Z8

1A38

16 High Standard (Full Height)

^Z9

1A39

24/32 Fancy

^Z8^E1

1A3805
31

24/32 High

^Z9^E1

1A3905
31

InView Message Format Continued

Message Attributes (Continued)

Insert Objects

Character Flash

Time

Date

Description

ASCII

Hex

Descriptio
n

ASCII

Hex

Description

ASCII

Hex

Flash ON

^G1

0731

Time

^S

13

MM/DD/YY

^K0

0B30

Flash OFF

^G0

0730

DD/MM/YY

^K1

0B31

MM-DD-YY

^K2

0B32

DD-MM-YY

^K3

0B33

MM.DD.YY

^K4

0B34

Advertising