Add a message on all displays, Adding a message on a specific display, Remove all messages on all displays – Rockwell Automation 2706-P42_P43_P44_P72_P74_P92_P94 InView Marquee Message Display User Manual User Manual
Page 73

Publication 2706-UM016D-EN-P - March 2006
InView Protocol 4-7
Add a Message on all Displays
This is an example of how to add message 2011 to all displays.
Add a Message on all Displays
Adding a Message on a Specific Display
The following adds message 348 to display address 055.
Adding a Message on a Specific Display
Remove all Messages on all Displays
The following removes all messages on all displays and automatically
displays the background message (4095) without adding the
background message number to the message queue.
The following removes all messages on all displays and add the
background message (4095) to the message queue using priority
messaging.
Remove a Message on all Displays
Name
[CTRL][T]
MSG #
Backslash
Function
Backslash
Display address Return
ASCII
^T
2011
\
2
\
255
^M
Hex
\14
\32\30\31\31
\5C
\32
\5C
\32\35\35
\0D
Name
[CTRL][T]
MSG #
Backslash
Function
Backslash
Display address
Return
ASCII
^T
348
\
2
\
55
^M
Hex
\14
\33\34\38
\5C
\32
\5C
\35\35
\0D
Name
[CTRL][T]
MSG #
Backslash
Function
Backslash
Display address Return
ASCII
^T
-1
\
3
\
255
^M
Hex
\14
\2D\31
\5C
\33
\5C
\32\35\35
\0D
Name
[CTRL][T]
MSG #
Return
ASCII
^T
4095
^M
Hex
\14
\34\30\39\35
\0D