InView Protocol 4-49

Set Date

This command is used to set the date.

Format for displaying the date is shown under insert object on
page 4-35.

Special Function command to set Time and Date

<SOH>

Type Code

Display Address

Description

ASCII

Hex

Description

ASCII

Hex

Description

ASCII

Hex

Start of Header

^A

01

All displays

Z

5A

Display Address

00

3030

Special Function command to set Time and Date Continued

<STX>

Command Code

Command

Function

Description

ASCII

Hex

Description

ASCII

Hex

Description

ASCII

Hex

Start of Text

^B

02

Write Special Function

E

45

Set Date

;

Special Function command to set Time and Date Continued

Command Code (Continued)

<ETX

Set Date

Set Hour and Minutes HhMm

ASCII

Hex

Description

ASCII

Hex

January 4, 2001 (Example)

010401

303130343031

End of Text

^C

03

December 5, 2002 (Example)

120502

313230353032

Special Function command to set Time and Date Continued

<STX>

Command Code

<ETX

Description

ASCII

Hex

Description

ASCII

Hex

Description

ASCII

Hex

Start of Text

^B

42

Set Time Format AM/PM

‘S

2753

End of Text

^C

03

Set Time Format 24Hr (Military)

‘M

274D