Ceiling mount -9, Ceiling mount – Rockwell Automation 2706-P42_P43_P44_P72_P74_P92_P94 InView Marquee Message Display User Manual User Manual
Page 17

Publication 2706-UM016D-EN-P - March 2006
Install InView Marquee Message Display 1-9
13. Torque the 5/16 nuts in the mounting holes (See Step 9) to
2.7 Nm (24 lb-in).
Ceiling Mount
To mount the display to the ceiling:
1. Remove one screw from the top of the end cap.
2. Line up a ceiling bracket with the top hole on the sign’s end cap
so the bracket fits in the indentation.
There are left and right ceiling brackets. Use the one that fits
with the screw hole’s countersunk side facing out.
3. Secure the ceiling bracket with the screw removed in Step 1 and
torque the screw to 2.7 Nm (24 in-lb).
4. Repeat steps 1 through 3 for the other end of the sign.
5. Use chains (not supplied) to hang the sign from a ceiling.
TIP
Use chains capable of supporting 4 times the total
weight of the sign(s).
TIP
The hole you select in the ceiling bracket for the
chain determines the angle at which the sign hangs.
Lock
nuts
Washers
Phillips
screws
Remove
this screw.
Ceiling
bracket
Ceiling
bracket
mounted to
end cap.
Screw hole Screw