Rockwell Automation 2706-P42_P43_P44_P72_P74_P92_P94 InView Marquee Message Display User Manual User Manual

Page 92

Advertising
background image

Publication 2706-UM016D-EN-P - March 2006

4-26 InView Protocol

Transmission:

Transmission for Clearing the Message Queue

Response: NONE

300 ms pause

2. Download Message #0001 to the appropriate memory position.

This stores the message in the message number used within the
data field. It overwrites any data already stored in the memory
position.

Transmission:

Download Message 1 to be Previewed

Response: NONE

300 ms pause

3. Trigger the message that was just downloaded.

Beginning
of Frame

ADDR

FUNC

H.O.

ADDR

L.O.

ADDR

DATA

LRC

Error

EOF

Ready to
rec. resp

:

FF

06

00

65

FFFF

98

CR

LF

TIP

Messages are downloaded to register 101 (40101),
which then moves the InView message to the
appropriate memory position.

Beginning
of Frame

ADDR

FUNC

H.O.

ADDR

L.O.

ADDR

DATA

EOF

Ready to
rec. resp

:

FF

01

00

64

^AZ00^BA2001^[”b^I^^1^\1Hello^D CR

LF

TIP

See section InView Display Communication Protocol
Functions and Descriptions on page 4-41
for further
explanation of the InView sign protocol being used.

Advertising