Rockwell Automation 2706-P42_P43_P44_P72_P74_P92_P94 InView Marquee Message Display User Manual User Manual

Page 24

Advertising
background image

Publication 2706-UM016D-EN-P - March 2006

1-16 Install InView Marquee Message Display

7. Connect the incoming serial wires per pinout.

TB1 can be used for incoming RS-485 or RS-232 serial
connection. They cannot be connected at the same time.

RS-485 is recommended to reduce undesirable electrical
interference.

TB1 Full

Pin

Pin Name

Pin

Pin Name

1.

GND

5.

RS-485(+)

2.

+5V

6.

RS-485(-)

3.

RS-232 TX

7.

NC

4.

RS-232 RX

8.

SHIELD

TB1 RS-485

Pin

Pin Name

Pin

Pin Name

1.

NC

5.

RS-485(+)

2.

NC

6.

RS-485(-)

3.

NC

7.

NC

4.

NC

8.

SHIELD

TB1 RS-232

Pin

Pin Name

Pin

Pin Name

1.

GND

5.

NC

2.

NC

6.

NC

3.

RS-232 TX

7.

NC

4.

RS-232 RX

8.

NC

Controller Board

1
2
3
4
5
6
7
8

TB1

Advertising