Chapter 2
Introduction to the DL50
2–5
➅ Configuration DIP Switches
Use these DIP switches to select:
•
Slave Address
•
Protocol (Simplex or Duplex)
•
Duplex Checksum (On or Off)
•
Character Height
•
DefaultColor (TriĆcolor displays)
•
Baud Rate
•
Mode Select
•
Hardware Type
Chapter 3 provides a complete description of these switches.
➆ RS-232 Port Connections
The RS-232 communications port allows point-to-point communications
between the DL50 and a host at distances of up to 50 feet (15.2 meters).
The following terminal connections are provided
:
Terminal Number*
Label
Definition
1
T
Transmit Line
2
R
Receive Line
3
G
Signal Ground
*
Terminal #1 is top terminal.
➇ RS-485 Port Connections
The RS-485 communications port allows multi-drop communications. The
cable distance between the last DL50 and host device (master) may be up to
4,000 feet (1219 meters). The following terminal connections are provided:
Label
Function
Definition
1
E. GND
Earth Ground
2
Shield
Shield
3
COM
Common
4
+
RS-485 + (B)
5
-
RS-485 - (A)
6
TERM
Termination
➈ Conduit Openings
External power and communications lines enter the enclosure through
these openings.