Installing the DL50

4–2

There are four methods of mounting the displays

:

Flush surface mount using the angle brackets supplied with the DL50.

Surface mount using optional adjustable brackets (Catalog No. 2706-NJ3)

Back-to-Back using adjustable brackets (Catalog No. 2706-NJ3).

Chain suspended (individually or back-to-back)

The displays are heavy. Proper installation techniques are
necessary to avoid injury from a falling display. Depending
upon the display and type of installation, two or more people
are required to install a display. Make sure the display is
installed on a structure able to accommodate the weight of the
display.

Catalog No. 2706-F11J, -F11JC: 40 pounds (18 kilograms)
Catalog No. 2706-F21J, -F21JC: 75 pounds (34 kilograms)

ATTENTION:

!

There are two methods of mounting the display on a vertical surface such as
a wall:

Directly mount the display to the wall using the angle brackets that are
factory-installed before shipment. See Figure 4.2.

Use the optional adjustable brackets (Catalog No. 2706-NJ3). See
Figure 4.3.

Mount the display only to concrete walls or steel/wood
beams. Do not mount the display on plaster or other soft
material walls. Failure to follow this warning could result in
personal injury or damage to the display.

ATTENTION:

!

The two flush wall-mount angle brackets (shipped pre-installed) may be
removed and attached to the wall, then the DL50 can be mounted on them.

!

ATTENTION:
All angle bracket bolts must be torqued to 53-61 in.-lbs.

Mounting Methods

Surface Mounting