Chapter 6

Slave Mode Operation / Examples

6–19

PLC String Variables

For this example, processor memory file #12 is set up as a string file which
contains the parts needed to form a message packet for a DL50 in Simplex
mode. Table 6.D has the variables for any Simplex mode communication,
and Table 6.E shows the strings for this example.

Table 6.D
Variables for Simplex Protocol and Their Functions

Memory

Location

Symbol

Description

ST12:0

MSG_SEND

The message which is built by the PLC and is actually sent out
to the DL50 through CH0

ST12:1

VARIABLE

The converted integer sample variable being appended to the
message

ST12:2

PRE_TEXT

The simplex protocol control byte (Field 1) and color code
(F11JC and F21JC only)

ST12:3

TEXT

The message text

ST12:4

F3_F4_F5

Fields 3, 4, and 5 of the simplex protocol
Field 3 determines the display mode
Field 4 determines the slave address
Field 5 determines the line number
These fields are followed by a \OD to produce a carriage return

The contents of these strings must be assigned using the off-line
programming software (6200). Control code values are entered into the
strings by using a forward slash followed by two hexadecimal digits. (See
Appendix B, which has hexadecimal values for all ASCII and extended
ASCII characters.)

Table 6.E
Strings Representing Control Code Values for This Example

Address

LEN

STRING TEXT

ST12:0

15

\19Temp 36\03\7F\01\0D

ST12:1

ST12:2

ST12:3

ST12:4

2

2

5

4

36

\02\19

Temp

\01\7F\01\0D

Note: Messages and attributes are changed by changing the strings or by
having the PLC append different pre-determined string numbers to the
MSG_SEND string.