Installing the DL50

4–19

The DL50 display may be connected to personal computers through an
RS-232 port. Either Simplex or Duplex protocol may be used in applications
with a personal computer as host.

For single-point connections of 50 feet or less, the DL50 RS-232 port
may be connected directly to the personal computer RS-232 port. See
Figure 4.16.

Figure 4.16
Personal Computer to DL50 RS-232 Port

RS-232 TxD (Transmit)

RS-232 RxD (Receive)

Signal Ground

DL50

RS-232 TERMINALS

T -

R-

G-

1

2

3

Signal Ground

RS-232 RxD (Receive)

RS-232 TxD (Transmit)

5

3

2

Computer
RS-232 port

DB-9 Connector

For installations greater than 50 feet, or for multi-drop networks
containing multiple DL50 displays, the personal computer can be
connected to a DL50 RS-485 network through a multi-point RS-232 to
RS-485 converter. See Figure 4.17.

A multi-point converter is used for:

single DL50 installations with a cable length over 50 feet, or

multi-drop network containing multiple DL50 displays.

Any RS-232 host (such as a personal computer) can be connected to a DL50
RS-485 network through a multi-point RS-232 to RS-485 converter such as
Black Box Corporation’s Model LD485A-MP.

Note: The output of LD485A-MP is a half-duplex RS-485 network that
will support up to 32 multi-dropped DL50 displays. Up to 100 DL50
displays can be connected when line drivers are installed.