Example 1 (Simplex Protocol)

Command Function: Display message shown below on all DL50 message
displays with an address of 42.

PRESSURE LOW

The command specifies a Roll up display mode

.

The host would need to send the following data (Simplex Protocol):

Ctrl-D

(Decimal 4)

P

(Decimal 77)

Field 2
ASCII Text

R

(Decimal 82)

Field 2
ASCII Text

E

(Decimal 69)

S

(Decimal 83)

S

(Decimal 83)

U

(Decimal 85)

R

(Decimal 82)

E

(Decimal 69)

8 of 12 bytes

9 of 12 bytes

SPACE

(Decimal 32)

L

(Decimal 76)

O

(Decimal 79)

W

(Decimal 87)

Field 2
ASCII Text

7 of 12 bytes

42

Decimal

2 of 3 bytes

3 of 3 bytes

1

Decimal

CR

(Decimal 13)

1 of 3 bytes

Field 3
Display Mode

Field 6
Carriage Return

Field 4
Slave Address

Field 5
Line Number

1 of 12 bytes

1 byte

2 of 12 bytes

3 of 12 bytes

4 of 12 bytes

5 of 12 bytes

6 of 12 bytes

10 of 12 bytes

11 of 12 bytes

12 of 12 bytes

Field 2
ASCII Text

Field 2
ASCII Text

Field 2
ASCII Text

Field 2
ASCII Text

Field 2
ASCII Text

Field 2
ASCII Text

Field 2
ASCII Text

Field 2
ASCII Text

Field 2
ASCII Text

Roll Up Message

Slave Address 42

Line #1

Message Text

Message Text

End Message

A simple BASIC program for a host PC to send the message would be:

100: Print #1, “PRESSURE LOW” + CHR$(4) + CHR$(42) + CHR$(1) + CHR$(13)