Chapter 6

Slave Mode Operation / Examples

6–23

PLC String Variables

For this example, processor memory file #12 is set up as a string file which
contains the parts needed to form a message packet for a DL50 in Duplex
mode. Table 6.G has the variables for any Duplex mode communication, and
Table 6.H shows the strings for this example.

Table 6.G
Variables for Duplex Protocol and Their Functions

Memory

Location

Symbol

Description

ST12:0

MSG_SEND

The message which is built by the PLC and is actually sent out
to the DL50 through CH0

ST12:1

VARIABLE

The converted integer sample variable being appended to the
message

ST12:2

PRE_TEXT

The duplex protocol control byte (Field 1) and color code
(F11JC and F21JC only)

ST12:3

TEXT

The message text

ST12:4

F3_F4_F5

Fields 3, 4, and 5 of the duplex protocol
Field 3 determines the slave address
Field 4 determines the line number
Field 5 is \OD to produce a carriage return

ST12:5

F6_B123

The three bytes of field 6 of the duplex protocol. This dield
controls the display mode, speed, and relay for each message.
Use the Duplex Field 6 Worksheet to determine hex values for
desired display operation.

ST12:6

CHECKSUM

Dummy checksum bytes appended to the end of the message.
Their actual value is not important, since the checksum
checking must be disabled on the DL50.
(Note: These bytes MUST NOT equal 13 or 18 decimal.)