Chapter 3

Configuring the DL50

3–6

Slave mode is the standard operating mode for the DL50. If the DL50 is not
operating properly, the Diagnostic mode will help isolate the problem (refer
to Chapter 8).

Operating Mode Switches

Mode

Switch Number S2-6

Switch Number S2-7

Slave Mode

OFF

OFF

Diagnostics Mode

OFF

ON

Reserved

ON

OFF

Reserved

ON

ON

This switch enables and disables the checksum for duplex protocol messages.
Duplex messages to the DL50 require a checksum field. However with the
checksum disabled, the contents of the checksum field are ignored.

Duplex Checksum Switch

Checksum

Switch Number S2-8

Enabled

ON

Disabled

OFF

This switch is factory set for the type of display hardware being used. Do not
change the setting of this switch. The chart below is for reference only.

Display Type Switches

Type

Switch Number S3-1

Switch Number S3-2

Catalog No. 2706-F11J

OFF

OFF

Catalog No. 2706-F21J

OFF

ON

Catalog No. 2706-F11JC

ON

OFF

Catalog No. 2706-F21JC

ON

ON

This switch applies to the tri-color displays (Catalog No. 2706-FllJC,
-F21JC). These switches have no affect on the single color displays. If a
message does not specify display colors, the default color is used.

Display Type Switches

Default Color

Switch Number S3-3

Switch Number S3-4

Red

OFF

OFF

Green

OFF

ON

Amber

ON

OFF

Reserved (Red)

ON

ON

Selecting Operating Mode

Enabling/Disabling
Checksum

Selecting Display Type

Selecting Default
Display Color