Publication 8720MC-IN001D-EN-P — December 2002

1-8

Installing Your 8720MC Drive

Ventilation Requirements

This section provides information to assist you in sizing your cabinet
and locating your 8720MC system components. Refer to Figure 1.3 for
minimum clearance requirements for 8720MC components mounted
inside the cabinet.

Figure 1.3
Minimum 8720MC Clearance Requirements)

Refer to Appendix A for 8720MC power dissipation specifications.

RST PRG ENT

REGENERATIVE POWER SUPPLY

8720

MC

8720

MC

HIGH PERFORMANCE DRIVE

8720

MC

HIGH PERFORMANCE DRIVE

152.4 mm

(6.0 in.)

101.6 mm

(4.0 in.)

101.6 mm

(4.0 in.)

152.4 mm

(6.0 in.)

152.4 mm

(6.0 in.)

152.4 mm

(6.0 in.)

152.4 mm

(6.0 in.)

UP

152.4 mm

(6.0 in.)

30725-M-R2

IMPORTANT

If the cabinet is ventilated, use filtered or
conditioned air to prevent the accumulation of dust
and dirt on electronic components. The air should be
free of oil, corrosives, or electrically conductive
contaminates.