Rockwell Automation 8720MC High Performance Drives Installation Manual User Manual

Page 49

Advertising
background image

Publication 8720MC-IN001D-EN-P — December 2002

8720MC Connector Data

2-15

Registration input specifications are shown in the table below. Refer to
figures 2.12 and 2.13 for the registration input configurations.

Figure 2.12 shows the connections required for the sensor inputs
when external (customer supplied +24V dc and/or 5V dc) power is
used.

Figure 2.12
Registration Interface Using External Power

Figure 2.13 shows the typical registration input connections. For
connecting the registration inputs use 2 wire, 1 twisted pair, #24 AWG
or larger, shielded cable. Alpha 6412 or equal.

Figure 2.13
Typical Registration Input Connections

Rating

Condition

Voltage

Position Latch
Time

Amperage

Hardware
Filtering

+5V dc

On

4 - 7.5V dc

1

µs

5 - 15 mA
less than 1.5 mA
leakage

800 ns

Off

less than 2V dc

+24V dc

On

17.5 - 38V dc

1

µs

Off

less than 6.9V dc

8720MC Drive

+24V dc Registration Input

+5V dc Registration Input

Registration Input Common

(P4-3)

(P4-2)

(P4-7)

24V dc sensor

5V dc sensor

+24V dc

PS

+5V dc

PS

sensor
switch

sensor
switch

8720MC +5V dc Return P4-8

or

8720MC +24V dc Return P5-23

Registration

input

P4-7 REG_COM

P4-2 +5V dc REG2
P4-3 +24V dc REG1

vcc

8720MC +5V dc P4-4

or

8720MC +24V dc P5-22

Advertising