Wiring i/o connections, Wiring i/o connections -27 – Rockwell Automation 8720MC High Performance Drives Installation Manual User Manual
Page 89
![background image](/manuals/580305/89/background.png)
Publication 8720MC-IN001D-EN-P — December 2002
Connecting Your 8720MC
3-27
Wiring I/O Connections
To wire your P1, P4, and P5 connectors:
1. Prepare your I/O wires by stripping approximately 12.7 mm (0.5
in.) of insulation from the end.
2. Use a small blade type screw driver and depress the spring clamp
next to the pin you will wire and insert the wire, as shown in
Figure 3.10 and Figure 3.11. The P4 and P5 wire terminations are
designed for stripped AWG 22 to AWG 14 wire.
Figure 3.10
P1 Connector
Figure 3.11
P4 and P5 Connector
3. Remove the screw driver and gently pull on the wire to make sure
it does not come out of its terminal. Re-insert and test any loose
wires.
IMPORTANT
Use caution not to nick, cut, or otherwise
damage strands as you remove the insulation.