Connecting your sercos fiber optic cables, Connecting your sercos fiber optic cables -22, Go to connecting your sercos fiber optic cables – Rockwell Automation 8720MC High Performance Drives Installation Manual User Manual

Page 84

Advertising
background image

Publication 8720MC-IN001D-EN-P — December 2002

3-22

Connecting Your 8720MC

Connecting Your SERCOS
Fiber Optic Cables

This procedure assumes you have your ControlLogix chassis with
1756-MxxSE interface and 8720MC SERCOS interface system(s)
mounted and are ready to connect the fiber-optic cables.

The SERCOS fiber-optic ring is connected using the SERCOS Receive
and Transmit connectors. Refer to Figure 2.4 for the location of the
connectors on your 8720MC drive(s) and Figure 3.8 to locate the
connectors on your 1756-MxxSE interface module.

Figure 3.8
SERCOS Fiber Optic Connections

Note: Fiber optic cable lengths of 0.3 m (4.0 in.) to 32 m (105.0 ft) are

available in plastic or glass. Lengths of 50 m (164.2 ft) to 200 m
(656.7 ft) are available in glass only.

SERCOS interface

TM

Tx (rear)

Rx (front)

OK

CP

SERCOS Receive Connector, Rx (front)

SERCOS Transmit Connector, Tx (rear)

1756-MxxSE SERCOS interface Module

Front View

Bottom View

Advertising