2. Route the motor power cable to the TB1 connector on your drive.

Refer to figures 2.1 and 2.3 for the location of TB1.

3.

4. Tighten the connections.

5. Gently pull on each wire to make sure it does not come out of its

terminal. Re-insert and tighten any loose wires.

6. Connect motor power to your motor.

7.

IMPORTANT

To ensure system performance, run wires and
cables in the wireways as established in
Chapter 1.

Insert the motor power wires from this
servo motor:

Into this
terminal on
8720MC Drive:

8720SM
(Customer Supplied)

MP-Series

TB1

U

U / Brown

U

V

V / Black

V

W

W / Blue

W

Green/Yellow

Shield

Shield

Clamp

If you have this
motor:

Do this:

MP-Series

Insert the motor end cable connector into the
motor power connector on the motor.

8720SM

Refer to the 8720SM High Performance AC
Induction Motors Installation Instructions

(publication 8720SM-IN001x-EN-P).

If your motor is:

Then:

8720SM

Go to Connecting Your SERCOS Fiber
Optic Cables
,
Connecting to the External
Active Shunt Module
, o
r Understanding
Feedback and I/O Cables
as n
eeded for
you application.

MP-Series

Go to Wiring the Motor Brake Connector
(MP-Series Motors Only)
.