Publication 8720MC-IN001D-EN-P — December 2002

A-6

Specifications and Dimensions

Contactor Ratings

The table below lists the recommended contactor ratings for 8720MC
drives and regenerative power supplies.

Note: For the contactor recommended for use with the

8720MC-RPS190, refer to the 8720MC Regenerative Power Supply
User Manual
(publication 8720MC-RM001x-US-P).

AC Line Filter
Specifications

The table below shows the specifications for AC line filters that you
can use with the 8720MC AC drives (8720MC-Bxxx) and regenerative
power supplies (8720MC-RPSxxx).

Catalog Number

Contactor

8720MC-B021

100-C23x10

8720MC-B027

100-C30x10

8720MC-B034

100-C37x10

8720MC-B042

100-C43x10

8720MC-B048

100-C60x10

8720MC-RPS027

100-C30x10

8720MC-RPS065

100-C72x10

8720MC
Component

AC Line Filter
Catalog Number

Specifications

Voltage

Phase

Current

Power
Loss

Weight

Humidity

Vibration

8720MC-RPS027 or
-RPS065

8720MC-RFI80

520V ac
50/60 Hz

Three

80A @ 50° C
(122° F)

25.9W

5.3 kg
(11.7 lb)

90% RH

10-200 Hz
@ 1.8 g

8720MC-RPS190

8720MC-EF190-VB

8720MC-B021 or
-B027

1336-RFB-27

460V ac
50/60 Hz

Three

27A @ 50° C
(122° F)

30W

5.0 kg
(11.0 lb)

90% RH

10-200 Hz
@ 1.8 g

8720MC-B034,
-B042, or -B048

1336-RFB-48

460V ac
50/60 Hz

Three

48A @ 50° C
(122° F)

56W

6.0 kg
(13.2 lb)

90% RH

10-200 Hz
@ 1.8 g

Advertising