High Speed Counter – 2080-MOT-HSC

Overview

The 2080-MOT-HSC plug-in module provides enhanced high speed counter
capabilities to the Micro800 controller. It supports the same functionalities of an
embedded high-speed counter on the Micro800 controllers but is enhanced to
support up to 250 KHz 5V differential line driver for improved noise immunity
and provides additional dedicated I/O.

The 2080-MOT-HSC module supports most commercial encoders (5V
differential or 24V single-ended).

Counter Specifications

Filter and decode inputs: 3 input points A, B, Z

These input points may come from different types and configurations of sensors.
The user must configure the module to respond to the type of sensor connected
to the module as described below.

IMPORTANT

To configure the plug-in module, you need to download and use the
HSC UDFBs from the Sample Code Library:

http://www.rockwellautomation.com/go/scmicro800

See

Quickstart Projects for 2080-MOT-HSC Plug-in on page 84

for

step-by-step instructions on how to use the plug-in with a sample
project.

Nominal Filter Settings

Maximum Guaranteed
Block Pulse Width

Minimum Guaranteed Pass
Pulse Width

No Filter – Default

250 kHz (DC 2

μs)

512 kHz (DC 0.95

μs)

265kHz (DC 1.9

μs)

200 kHz (DC 2.5

μs)

333 kHz (DC 1.5

μs)

201 kHz (DC 2.48

μs)

80 kHz (DC 6.25

μs)

128 kHz (DC 3.9

μs)

86.7 kHz (DC 5.8

μs)

40 kHz (DC 12.5

μs)

62.8 kHz (DC 8.0

μs)

42.5 kHz (DC 11.6

μs)

13.3 kHz (DC 35

μs)

20.8 kHz (DC 24.1

μs)

14.1 kHz (DC 35.5

μs)

10 kHz (DC 50

μs)

15.7 kHz (DC 32.1

μs)

10.5 kHz (DC 47.2

μs)

4 kHz (DC 125

μs)

6.3 kHz (DC 80.3

μs)

4.2 kHz (DC 119

μs)

2 kHz (DC 250

μs)

3.2 kHz (DC 161

μs)

2.1 kHz (DC 237

μs)

1 kHz (DC 0.5 ms)

1.6 kHz (DC 0.33 ms)

1.0 kHz (DC 0.48 ms)

500 Hz (DC 1 ms)

778 Hz (DC 0.65 ms)

527 Hz (DC 0.95 ms)

250 Hz (DC 2 ms)

389 Hz (DC 1.3 ms)

263 Hz (DC 1.9 ms)