Configuration for UDFB 1: RA_HSCPlugIn

1.

Launch Connected Components Workbench. Open the sample project
you have downloaded from the Sample Code Library.

2.

Import the RA_HSCPlugIn UDFB you have downloaded into this
project. Note that the sample project will have the following input and
output parameters.

NOTE: The purpose of this UDFB is to get
high speed counter accumulator value and
current pulse frequency.

Input and Output Parameters

Parameter

Type

Data Type

Description

FBEN

INPUT

BOOL

Function block Enable input

SlotID

INPUT

UINT

Plug-in slot number.
Slot ID = 1…5 (starting with the far left slot 1)

NoiseFilter

INPUT

USINT

00: No filter
01: 250 kHz
02: 200 kHz
03: 80 kHz
04: 40 kHz
05: 13.3 kHz
06: 10 kHz
07: 4 kHz
08: 2 kHz
09: 1 kHz
10: 500 Hz
11: 250 Hz
12: 125 Hz
13: 63.5 Hz
14: 31.25 Hz

HSCMode

INPUT

USINT

0, 2 , 4, 6, 8, 10, 12

Start

INPUT

BOOL

Start counter.

Stop

INPUT

BOOL

Stop the counter and clear “MaxDPos” and
“MaxDSpd” value.

FBENO

OUTPUT

BOOL

Function block Enable output

IDCHeck

OUTPUT

BOOL

TRUE: HSC plug-in is at selected slot.
FALSE: Wrong plug-in or no plug-in at selected slot.