• IF FBEN is False, then all outputs are cleared and accumulator is cleared

and when FBEN goes true again, the HSC will be reinitialized.

Configuration for HSC UDFB 3: RA_ServoFDBK

1.

Launch Connected Components Workbench and open the sample project
you have just downloaded from the Sample Code Library.

2.

Import the RA_ServoFDBK UDFB into this project.
Note that the UDFB comes with the following input and output variables.

NOTE: This UDFB gets positioning information of a
PTO axis that is controlled by a Micro800 controller
with HSC plug-in installed.

Input and Output Parameters

Parameter

Type

Data
Type

Description

FBEN

INPUT

BOOL

Function block Enable input

SlotID

INPUT

UINT

Plug-in slot number.
Slot ID = 1…5 (starting with the far left slot 1)

HomePos

INPUT

REAL

Home position.
Same value indicated in MC_Home instruction.