Torque specifications for the 2080-dnet20 plug-in – Rockwell Automation 2080 Micro800 Digital and Analog Plug-in Modules User Manual

Page 80

Advertising
background image

72

Rockwell Automation Publication 2080-UM004B-EN-E - December 2013

Appendix A Specifications

Torque Specifications for the 2080-DNET20 Plug-in Module

Mounting torque 0.2 Nm

Mounting torque 0.3 Nm

Mounting torque:
0.5…0.6 Nm

46209

ATTENTION: To comply with CE Low Voltage Directive (LVD), this
equipment and all connected I/O must be powered from a source
compliant with the following: Safety Extra Low Voltage (SELV) or
Protected Extra Low Voltage (PELV).

ATTENTION: To comply with UL restrictions, this equipment must be
powered from a source compliant with the following: Class 2 or Limited
Voltage/Current.

Environmental Specifications – 2080-DNET20

Attribute

Value

Temperature, operating

IEC 60068-2-1 (Test Ad, Operating Cold),
IEC 60068-2-2 (Test Bd, Operating Dry Heat),
IEC 60068-2-14 (Test Nb, Operating Thermal Shock):
-20…65 °C (-4…149 °F)

Temperature, surrounding air, max. 65 °C (149 °F)

Temperature, nonoperating

IEC60068-2-1 (Test Ad, Operating Cold),
IEC60068-2-2, (Test Bd, Operating Dry Heat),
IEC 60068-2-14 (Test Nb, Operating Thermal Shock):
-40...85 °C (-40…185 °F)

Relative humidity

IEC 60068-2-30 (Test Db, Unpackaged Damp Heat):
5…95% noncondensing

Emissions

CISPR 11 (IEC 61000-6-4):
Class A

ESD Immunity

IEC 61000-4-2:
6 kV contact discharges
8 kV air discharges

Radiated RF immunity

IEC 61000-4-3:
10V/m with 1 kHz sine-wave 80% AM from 80…2000 MHz
10V/m with 200 Hz 50% Pulse 100% AM @ 900 MHz
10V/m with 200 Hz 50% Pulse 100% AM @ 1890 MHz
10V/m with 1 kHz sine-wave 80% AM from 2000…2700 MHz

Advertising