Preface

ControlGuardian User’s Guide

5-10

Figure 5.C

Configure Auto Batch Parameters

If you want to:

Press this key:

Select the device type to which the uploaded file will be compared.

Choose between PLC-5, PLC-3, PLC-2, SLC 500, or PLC-5, PLC-3,

PLC-2, and SLC 500. The default is PLC-5.

F1

Device Type to Upload

Use the WHO active screen to select a station. When you select WHO
active, ControlGuardian displays a map of the devices on link. Move the
cursor to the device you want to upload from and press

and

F1

ControlGuardian inserts the station number for your compare action.

F2

Ctrl

WHO Active

Select the communication hardware device. For more information, see

chapter 3.

F3

Communications Device

Select the report configuration.

This file defines how the report should print. To create a new report

format, see chapter 10.

F4

Report Format

Select a report type:
·ladder logic
·data table
·ladder logic and data table

F5

Report Type

Select the action type:
·Upload & Compare - uploads the working program from the selected

processor and compares it to the master file.

·Upload Only - uploads the working program from the selected

processor and places the file in the production directory.

·Upload/B-Compare - uploads the working program from the processor

and binary compares the ladder logic to the ladder logic in the master

file. Creates an AUTO.ERR file to record matches and mismatches.

·Upload/Smart Compare - uploads the working program from the

processor and binary compares it to the master file. Generates a

detailed compare report if the ladder logic from the working file and the

master file mismatch.

F6

Action Type