Hapter, Introduction, 1 conventions used in this manual – Rockwell Automation SP120 ACDrive 115VAC, 1Ph, 230VAC, 1Ph/3Ph, 1/4-5.0HP User Manual

Page 11: 2 model number description

Advertising
background image

Introduction

1-1

English

C

HAPTER

1

Introduction

This chapter describes the SP120 AC drive and how to identify it based on its model
number. It also provides receiving information and a description of the drive
nameplate and other features.

Refer to Appendix A for specifications and mounting dimensions for the SP120 line
filter modules.

1.1

Conventions Used in This Manual

To help differentiate parameter names and parameter settings from other text
the following conventions will be used:

Parameter numbers and names are shown in the following way:
d01 [

OUTPUT

FREQUENCY

]

Parameter settings for inputs and outputs are shown with the setting number
followed by the alpha description in {braces}. For example, 18{RS}.

1.2

Model Number Description

Figure 1.1 below describes the SP120 AC drive model numbering structure. Note that
not all combinations can be configured as a drive. Refer to Appendix A,

Technical

Specifications, for more information.

Figure 1.1 – Model Number Structure

S12 - 2 0 1P4 L U

S12 = SP120

Voltage Rating
1 = 115 VAC (

)

2 = 230 VAC (

or

)

4 = 460 VAC (

)

Enclosure Type
0 = protected chassis IP20

Output Current
1P4 = 1.4 A (0.25 HP (0.2 kW) @ 230 V) 5P0 = 5.0 A (1.5 HP 1.1 kW) @ 230 V)
1P5 = 1.5 A (0.5 HP (0.4 kW) @ 460 V) 5P5 = 5.5 A (3 HP (0.4 kW) @ 460 V)
2P5 = 2.5 A (1 HP (0.75 kW) @ 460 V) 7P1 = 7.1 A (2.0 HP (1.5 kW) @ 230 V)
2P6 = 2.6 A (0.5 HP (0.4 kW) @ 230 V) 8P6 = 8.6 A (5 HP (3.7 kW) @ 460 V)
3P0 = 3.0 A (0.75 HP (0.55 kW) @ 230 V) 010 = 10 A (3.0 HP (0.4 kW) @ 230 V)
3P8 = 3.8 A (2 HP (1.5 kW) @ 460 V) 015 = 15 A (5.0 HP 3.7 kW) @ 230 V)
4P0 = 4.0 A (1.0 HP (0.75 kW) @ 230 V)

L = Keypad
D = DeviceNet

U = 60 Hz (Default)