Line filter module specifications, English – Rockwell Automation SP120 ACDrive 115VAC, 1Ph, 230VAC, 1Ph/3Ph, 1/4-5.0HP User Manual

Page 66

Advertising
background image

A-10

SP120 AC Drive Installation and Operation

English

Line Filter Module Specifications

Current: at 40 °C ambient temperature

Overload: 150% IN for 10 min

Frequency: 50/60 Hz

Material: steel, surface refined

Humidity class: C

Operation height: < 1000 m without derating
> 1000 m, I

N

-2%, for each 1000m

Temperature range: -25 °C to +85 °C

Connections: Input terminals IP 20 and PE-screw M5
Load side: cable, unshielded

Line Filter

Module

Nominal

Voltage

(V)

Nominal

Current at

40

°

C (A)

Leakage

Current at

50 Hz

(mA)

Test voltage

(VDC for 2 sec)

ph./ph.;

ph./ground

Input wire max.

cross section

(mm

2

)

L/N

Output cable

cross section

(mm

2

)

Heat

dissipation

(W)

S12-MF1-1010 100-120

10

< 3.5

N/A

4/4

3x1.5

N/A

S12-MF1-1016 100-120

16

< 3.5

N/A

4/4

3x1.5

N/A

S12-MF1-Y007 200-240

7

< 3.5

1400 / 2800

4/4

3x1.5

6

S12-MF1-Y012 200-240

12

< 3.5

1400 / 2800

4/4

3x1.5

7

S12-MF1-Y022 200-240

22

< 10

1400 / 1400

4/4

3x2.5

9

S12-MF1-2004 200-240

4

< 3.5

1400 / 2800

4/4

4x1.5

N/A

S12-MF1-2007 200-240

7

< 3.5

1400 / 2800

4/4

4x1.5

N/A

S12-MF1-2020 200-240

20

< 3.5

1400 / 1400

4/4

4x2.5

N/A

S12-MF1-4007 380-460

7

< 3.5

1978 / 2800

4/4

4x1.5

7

S12-MF1-4011 380-460

11

< 3.5

1978 / 2800

4/4

4x2.5

10

0

0,2

0,4

0,6

0,8

1,0

20

40

60

80

100

Temperature in °C

0

I

B

I

N

1,2

Dependence of current on ambient temperature

Advertising