Parameters and Programming

3-15

English

Parameter

Number

Parameter Name/ Description

Min./Max

Range

Units

Factory

Default

Second Acceleration/Deceleration Ramp

*A92

Accel Time 2
Time for the drive to ramp from 0.0 Hz to A04 [

MAXIMUM

FREQUENCY

]. A94 [

ACCEL

/

DECEL

2

SELECT

] is used to

determine when active.
This parameter can be changed while motor is running.

0.1 to 3000

<1000, 0.1 s
>1000, 1 s

15.0

*A93

Decel Time 2
Sets the time for the drive to ramp from A04 [

MAXIMUM

FREQUENCY

] to 0.0 Hz. A94 [

ACCEL

/

DECEL

2

SELECT

] is

used to determine when active.
This parameter can be changed while motor is running.

0.1 to 3000

<1000, 0.1 s
>1000, 1 s

15.0

A94

Accel / Decel 2 Select
Used to determine when the A92 [

ACCEL

TIME

2] and

A93 [

DECEL

TIME

2] are used.

Settings: 00=Digital inputs (C01-C05) set to 09{2CH}
01=Automatic if frequency programmed in
A95 [

ACCEL

2

START

FREQUENCY

]/

A96 [

DECEL

2

START

FREQUENCY

] is reached.

00 to 01

Numeric
Value

00

A95

Accel 2 Start Frequency
Sets the frequency at which A92 [

ACCEL

TIME

2] will take

effect if A94 [

ACCEL

/

DECEL

2

SELECT

] is set to 01.

0.0 to 360.0

0.1 Hz

30.0

A96

Decel 2 Start Frequency
Sets the frequency at which A93 [

DECEL

TIME

2] will take

effect if A94 [

ACCEL

/

DECEL

2

SELECT

] is set to 01.

0.0 to 360.0

0.1 Hz

30.0

A97

Accel Curve
Selects the type of acceleration curve.
Settings: 00=Linear
01=S-curve

00 to 01

Numeric
Value

00

A98

Decel Curve
Selects the type of deceleration curve.
Settings: 00=Linear
01=S-curve

00 to 01

Numeric
Value

00