Parameters and Programming

3-11

English

Parameter

Number

Parameter Name/ Description

Min./Max

Range

Units

Factory

Default

Preset Frequencies (continued)

*A21

Preset Frequency 1

The programmed value sets
the frequency that the drive
outputs when selected. (Refer
to digital input settings table in
Chapter.2).

Note: If a preset frequency
input is active, the keypad
frequency pot and analog
frequency commands will be
ignored.

Note: The value of any Preset
Frequency can be changed via
F01 [

FREQUENCY

COMMAND

]

when the Preset Frequency is
activated via the digital inputs.

These parameters can be
changed while motor is
running.

0.0 to 360.0

0.1 Hz

0.0

*A22

Preset Frequency 2

0.0 to 360.0

0.1 Hz

3.0

*A23

Preset Frequency 3

0.0 to 360.0

0.1 Hz

5.0

*A24

Preset Frequency 4

0.0 to 360.0

0.1 Hz

10.0

*A25

Preset Frequency 5

0.0 to 360.0

0.1 Hz

15.0

*A26

Preset Frequency 6

0.0 to 360.0

0.1 Hz

20.0

*A27

Preset Frequency 7

0.0 to 360.0

0.1 Hz

25.0

*A28

Preset Frequency 8

0.0 to 360.0

0.1 Hz

30.0

*A29

Preset Frequency 9

0.0 to 360.0

0.1 Hz

35.0

*A30

Preset Frequency 10

0.0 to 360.0

0.1 Hz

40.0

*A31

Preset Frequency 11

0.0 to 360.0

0.1 Hz

45.0

*A32

Preset Frequency 12

0.0 to 360.0

0.1 Hz

50.0

*A33

Preset Frequency 13

0.0 to 360.0

0.1 Hz

55.0

*A34

Preset Frequency 14

0.0 to 360.0

0.1 Hz

60.0

*A35

Preset Frequency 15

0.0 to 360.0

0.1 Hz

0.0

*A38

Jog Frequency
This parameter sets the frequency the drive will output
when it receives a valid jog command.
This parameter can be changed while motor is running.

0.5 to 9.9

0.1Hz

5.0

A39

Jog Stop Mode
This parameter sets the stop method when the jog input
is removed.
Settings: 00=Coast
01=Ramp
02=DC Brake (See A53 [

DC

WAIT

TIME

] –

A55 [

DC

HOLD

TIME

])

00 to 02

Numeric
Value

01