routecache <0-65535> – Configures IP route cache
usage. Set a value between 0 and 65553.
•
temperature <1-6> [critical|high|low] – Sets the
number of temperature sensors for the controller.
•
critical <0.0 - 250.0> – Critical temperature limit
•
high <0.0 - 250.0>
– high temperature limit
•
low <0.0 - 250.0>
– low temperature limit
•
period <100-30000> – Configures the diagnostics period.
Set a value between 100-30000 milliseconds. The default
value is 1000 milliseconds.
•
poe debug - Power over Ethernet
•
debug - Enables debugging
•
tech-support-period <10-10080> – Sets diagnostics
tech-support-period
•
<10-10080>
– The default 1440
minutes (1 day)
•
tech-support-url <URL>– Set the URL to use during auto
generated technical support dumps
•
<URL>
–
URL to which to copy
•
tftp://<hostname|IP>[:port]/path/file
•
ftp://<user>:<passwd>@<hostname|IP>[:port]/p
ath/file
•
sftp://<user>@<hostname|IP>[:port]>/path/file
encrypt secret 2
<pass-phrase> plaintext
<plain-text>
Encrypts a password or key with a secret passphrase
•
secret – Encrypts passwords/keys with a secret phrase
•
2 – Type of encryption SHA256-AES256
•
<pass-phrase> – Defines the passphrase used for
encryption
•
<plain-text> – Defines the plain text password or key to
encrypt
kill connection {<1-64>}
Kills a connection using ESPI Adapter index
•
connection {<1-64>} – A single optional ESPI Adapter index
<1-64>
locator
Locates the controller by flashing all LEDs.
save-cli
Saves the CLI tree for all modes in HTML