Ultra-cut 400, 03 internal coolant filter cleaning procedure, 04 coolant replacement procedure – Tweco 400 Ultra-Cut(March 2013) User Manual

Page 100

Advertising
background image

MAINTENANCE 5-2

Manual No. 0-5163

ULTRA-CUT 400

5.03 Internal Coolant Filter Cleaning Procedure

The in-line filter screen should be cleaned periodically. To gain access to the In-Line Filter Assembly remove the

right side panel (viewed from the front of unit) of the Power Supply. Remove the filter screen by unscrewing the

filter holder from the In-Line Filter Assembly. Clean the filter screen by rinsing with hot soapy water. Remove soap

residue by rinsing with clean hot water. Be sure that all the soap has been removed and the screen is dry of water

before re-installing in the In-Line Filter Assembly.

5.04 Coolant Replacement Procedure

Replace coolant as follows:

1. Disconnect the system from main input power. At the bottom of the coolant tank, disconnect the coolant line

fitting and collect coolant in a disposable container.

2. Connect the system to main input power and turn it on to allow the pump to empty the tank. The pump will

run approximately for 20 seconds before the flow switch causes an interlock. This procedure may be repeated
a few times until the tank is completely empty.

3. Connect the coolant line fitting and fill the tank with fresh coolant until the right level is reached.

COOLANT

RETURN

SUPPLY

RETURN

SUPPLY

Art # A-09460

Fill Range

Coolant Tank

4. Turn system on, let it run for a few minutes and check coolant level, refill if necessary.

Advertising