Ultra-cut 400, 12 set switches on the command - control module – Tweco 400 Ultra-Cut(March 2013) User Manual

Page 46

Advertising
background image

INSTALLATION

3-20

Manual No. 0-5163

ULTRA-CUT 400

3.12 Set Switches on the Command - Control Module

Compare the command - control module to the illustration.

Remove the power supply right side. Set switches on the CCM (Command-Control Module) per the illustrations.

Switch settings, jumpers and connection details are provided in the Appendix. Changes require recycling of power.

CAUTION

Printed circuit boards in the Command - Control Module are static - sensitive. Discharge any built-up static
charges in your body or surroundings before touching the printed circuit boards.

SW1

SW3

SW4

SW5

SW8

3

4

1

2

3

4

1

2

1

2

1

2

1

2

1

2

SW-1-1: Auto Pilot Restart. 1 = ON = Auto Pilot Function enabled.
1 = OFF = Auto Pilot Function disabled (Factory default setting).
SW-1-2: Pilot Delay 2 = OFF, 3 = OFF, 4 = OFF: 0 Seconds (Factory default setting).
SW-1-3: Pilot Delay 2 = ON, 3 = OFF, 4 = OFF: 0.1 Seconds
SW-1-4: Pilot Delay 2 = OFF, 3 = ON, 4 = OFF: 0.2 Seconds
2 = ON, 3 = ON, 4 = OFF: 0.4 Seconds
2 = OFF, 3 = OFF, 4 = ON: 0.8 Seconds
2 = ON, 3 = OFF, 4 = ON: 1.0 Seconds
2 = OFF, 3 = ON, 4 = ON: 1.5 Seconds
2 = ON, 3 = ON, 4 = ON: 2.0 Seconds

SW-4: Postflow Time 1 = OFF, 2 = OFF: 10 Seconds (Factory default setting).
1 = ON, 2 = OFF: 20 Seconds
1 = OFF, 2 = ON: 5 Seconds
1 = ON, 2 = ON: 0 Seconds
SW-5-1: Tip Saver Reserved for Factory use.

SW-5-2: Off Plate

Reserved for Factory use.

SW 8-1: Pilot Time OFF = Short (85 ms.) (Factory default setting).

ON = Long (3 s.)

O
N

O
N

Active only when
SW-1-1 is set to O N.

Art # A-09457

Future Use

SW-3: Gas Preflow Time 1 = Off, 2 = OFF: 2 seconds

1 = ON, 2 = OFF: 4 seconds

1 = OFF, 2 = ON: 6 seconds

1 = ON, 2 = ON: 8 seconds

SW 8-2: Remote Current OFF = Disabled (Factory default setting).

ON = (Remote Analog Current Control)

*SW 8-3: Auto Transfer Retry OFF = Enabled Up to 3 tries (Factory default setting).

ON = Disabled

SW 8-4: Remote Marking OFF = Disabled (Factory default setting).

ON = Remote Marking SW Enabled at TB3-1&2

* SW 8-3 is reserved for

Factory use prior to

Firmware V3.5

Advertising