SPECIFICATIONS 2-2

Manual No. 0-5163

ULTRA-CUT 400

Ultra-Cut 400 Power Supply
Input

Power Input

Current

Suggested Sizes (See Note)

Voltage

Freq.

3-Ph

3-Ph

Fuse (Amps)

Wire (AWG)

Wire (mm2)

(Volts)

(Hz)

(kVA)

(Amps)

3-Ph

3-Ph

3-Ph

208

50/60

119

336

350

300MCM

150

230

50/60

119

304

350

250MCM

150

460

50/60

116

148

175

#1

50

380

50/60

120

183

225

1/0

70

400

50/60

120

174

225

1/0

70

* Suggested wire size based on United States NFPA 70 National Electrical Code 2005 edition published by the National

Fire Prevention Association.

Listings are from table 400.5(B) for flexible cord of certain types rated for 75 deg C in ambient temperatures up to 30 deg

C. Using wires of lower temperature rating or different insulation type may require larger wire size. Derate for higher

ambient.

These are suggestions only. Always refer to your local and national codes that apply to your region for final determination

of correct wire type and size.

2.07 System Component Layout

Primary power

Work

CNC

Remote

Arc

Starter

Art # A-09448

Torch

Coolant Supply 10’

Coolant Return 10’

Control Cable

Pilot Return

Coolant Supply

Coolant Return

Plasma Gas

Shield Gas

Work Cable

DMC-3000

Gas

Console

Ultra-Cut

Power
Supply

DPC-3000

Gas

Control

Positioning Tube

Plasma Gas

Marking

Shield

Shield Gas

Negative 2/0

Pilot Return #8

Control Cable

50’ / 15.25 m Maximum Length

Shield

H

Q

R

U

S

A

B

E

C

D

P

K

L

O

I

J

G

175’ / 53.3 m Maximum Length

Preflow

Fiber Optic

L

Water Shield

T

F

125’ / 38.1 m Maximum Length

175’ / 53.3 m Maximum Length

Fiber Optic

Control Cable

F

Ground Cable

Only When
DMC Mounted
On Top Of PS

Touch

Screen

Controller

V

W

F1

F1

F

F

HE 400
Heat
Exchanger

Control Cable

C

D

Y

C
C
M

Coolant Supply

Coolant Return

Advertising