4-15 OPERATION

ULTRA-CUT 400

4.11 Power Supply Status Codes

On start-up and during operation, the power supply control circuitry performs various tests. If the circuitry
detects a condition requiring operator attention, the status indicator on the control panel flashes a 2-part code
to indicate a code group and then a particular condition within the group. After 4 seconds, the sequence
repeats.

Example: Indicator flashes 4 times; the condition is in group 4. After a 1.2 second delay, the indicator blinks
3 times; the condition code is 4-3, indicating that the coolant is overheating. After a 4-second delay, the
indicator repeats the sequence until the condition is corrected.

Some conditions can be active indefinitely, while others are momentary. The power supply latches momen-
tary conditions; some momentary conditions can shut down the system. The indicator may show multiple
conditions in sequence; it is important to recognize all possible conditions that may be displayed.

Note

These codes are for systems with Firmware versions 2.4 or later. If your system’s Firmware is a prior version,
contact your distributor for updates.

CCM Status Code

Code

Message

Remedy / Comments

Group 1 -- Plasma Process

1-1

Plasma Disabled or

Missing AC Input

Phase

Plasma Enable Off ; External Disable / E-Stop Activated or CCM TB1-

1&2 jumper missing; Control cable to DMC not connected; Missing AC

Phase.

1-2

Pilot Ignition Failure

Pilot did not start within 15 seconds. Ensure process loaded agrees

with torch parts installed; Torch consumable parts worn; Defective Arc

Starter. Defective chopper (100-300A unit); Defective #2 inverter (400A

unit).

1-3

Lost Pilot

Pilot went out while CNC Start active Ensure process loaded agrees

with torch parts installed; If custom process cut current too low or

preflow pressure too high. Torch consumable parts worn

1-4

Transfer Lost

Arc was transferred to work for more than 50 ms and then went out

while CNC Start still active. Standoff too high; Ensure process loaded

agrees with torch parts installed; If custom process current set too low

or wrong plasma pressure.

1-5

Off the Plate

Function not currently enabled

1-6

Pilot Timeout, no

Transfer

Must transfer from Pilot to Cutting Arc in 85 ms. (SW8-1 OFF) or 3 sec.

(SW8-1 ON). Standoff too high or void in work under torch; Wrong cut

process selected resulting in: Pilot current too low for consumables;

Preflow pressure too low.

1-7

Reserved

No information available; Contact customer service

1-8

Possible Shorted Torch

Tip voltage too close to electrode voltage. Plasma supply pressure

too low; Leak in Plasma hose to torch; Ensure process loaded agrees

with torch parts installed; If custom process, plasma pressure may be

too low or cut current too high. Torch consumable parts worn; Shorted

torch body

1-9

Part Process not con-

figured

CNC Start applied without a process loaded. Select process and send to

plasma system

1-10 Device Locked

Process loading, wait until finished