Ultra-cut 400 – Tweco 400 Ultra-Cut(March 2013) User Manual
Page 41
Manual No. 0-5163
3-15 INSTALLATION
ULTRA-CUT 400
Art # A-09418
3. Once the fiber cable is installed in the CCM or gas control make sure the strain relief nut is securely tightened
onto the hose so the hose can’t pull out of it like this:
Art # A-09677
Hose not secured in
the Strain Relief
Correct installation:
Correct way to pull the cable is to use a snake or a wire or another cable and attach it securely to the hose behind the
strain relief. Then secure the fiber connector to the pulling device leaving some slack in the fiber. Keep the protec-
tive end covers on the fiber until you are ready to connect it to the PCB in the CCM or gas control.
Art # A-09420
Correct installation in CCM or Gas Control leaves a loop of fiber so there is no stress on the fiber where it exits the
connector or the hose.