INSTALLATION

3-8

Manual No. 0-5163

ULTRA-CUT 400

3.06 Connect Work Cable and Pilot and Negative Leads

1. Pass the ends of the work cable and pilot and negative leads upward through the leads bracket at the bottom

edge of the rear panel, then through the openings in the connections cover support panel.

2. Refer to the illustration. Connect the leads as shown. Tighten securely. Do not overtighten.

CAUTION

The clear connections cover must remain in place.

PILOT

WORK

TORCH

Connection Panel

AC INPUT

L1

L2

L3

Work Lead

Torch Lead - To Remote Arc Starter

Work

Torch

Lead Connection Detail

Connections Cover

Support Panel

Art # A-07660_AB

Connections Cover

Pilot

To Cutting Table

Leads Bracket

Pilot Lead -

To Remote Arc Starter

3. Re-install the connections cover on the power supply. Snug the hardware securely by hand. Do not overtighten.