INSTALLATION
3-32
Manual No. 0-5163
ULTRA-CUT 400
3.17 Fiber Optic Cable Installation from CCM to DMC-3000.
CAUTION
Avoid kinking, twisting, or bunching the fiber optic cable. The cable can be damaged by being forced into
tight-radius turns. Review section 3.10 for proper handling and installation of fiber optic cable.
1. Remove outer thin nut from through hole protector at the end of Fiber Optic Cable (L) that is connected to
the CCM.
2. Ensure that the cable is exposed beyond the through hole protector approximately 1” (as shown below) and
secure by tightening the wide nut with the rounded end while holding the other nut in place. Normal hand
tightening is not enough.
3. Feed the Fiber Optic Cable plug and wires through the hole where shown then slide the thin nut back over
the Fiber Optic Cable.
Art # A-09148
4. Secure the thin nut on the through hole protector so both nut faces are tight against the sheet metal inside
and out.