OPERATION

4-16

Manual No. 0-5163

ULTRA-CUT 400

CCM Status Code

Code

Message

Remedy / Comments

Group 2 -- Plasma Power Supply

2-1

Missing AC Phase

Blown fuse, Broken or loose connection on power cable

2-2

Wrong input voltage

Inverter(s) not configured correctly for input voltage;

Poor power quality (brownouts, dropouts); Input power capacity / wiring too small causing

voltage drop; broken or loose power cable connections.

2-3

Inverter Over Tempera-

ture

Ambient above 40 deg C. (104 F); Blocked airflow.Failed fan; Defective inverter.

2-4

Power Supply not Ready Defective inverter; PCB4; PCB7; defective input contactor.

2-5

DC Output Low

Less than 60 VDC; Defective inverter, shorted output; CCM voltage sense (J6) wire open or

disconnected. Negative lead short to gnd. Shorted chopper (100-300A only).

2-6

Inverter input fault

Capacitor bank voltage imbalance (400-460-600V only) or inverter primary switching circuit

overcurrent. If occasional may be line voltage surge; remove power to reset. If persists

defective inverter; LED on inverter indicate which one.

2-7

Unexpected current

Current above 20A in work or pilot leads before pilot ignition; Possible shorted torch; Defec-

tive current sensor.

2-8

Unexpected current in

pilot circuit

Current above 5A in pilot circuit; wrong or mismatched consumables; Pilot lead shorted to

negative in torch tube; Possible shorted torch

2-9

Unexpected current in

work lead

Current above 5A in work lead; Short to chassis in RAS; Negative lead short to ground.

2-10

Output Current Too High Current greater than 20% above process setting. Measure current of each inverter, only one

high likely defective inverter. All high likely defective PCB5, CCM.

2-11

Output Current Too Low Current more than 20% below process setting. Measure current of each inverter, only one

low likely defective inverter. All low likely defective PCB5, CCM.

Group 3 -- Gas Controller Status & Protocol

3-1

Gas Control Communi-

cation fault.

Cannot establish Communication with gas control. DMC to DPC Control Cable not con-

nected or Fiber-optic cable not properly connected, dirty or defective; DPC power supply or

Control PCB defective. DMC Control PCB defective; CCM defective, replace.

3-2

Gas Control reply fault. Connection was established but Gas Control did not reply to the CCM in the allowed time

(15 ms.). Dirt on fiber ends or in connectors, blow out with clean dry air. Fiber not locked

into connector; sharp bends in fiber; fiber defective. If it’s determined the fiber is OK then

DPC or DMC Control or Power Supply PCB likely defective, replace board.

3-3

Gas Supply Pressure out

of range.

DPC has detected a pressure error, Check DPC status indicator for specific problem.

3-4

Gas Control Purging

The time to purge depends on Lead Length, previous fluids used, and current process fluids

selected. Wait until finished.

3-5

Gas Control Protocol

Error

Verify Firmware revison for compatiblity with DMC and DPC

3-6

Reserved

No information available; Contact customer service

3-7

Gas Control sequencing

error

Verify Firmware revison for compatiblity with DMC and DPC

3-8

Gas Control Type Mis-

match

CCM must be Ultracut type with USB for use with Auto Gas Control (DFC-3000)

3-9

Gas Control Command

fault

Verify Firmware revison for compatiblity with DMC and DPC; Elctromagentic interference

with Arc Starter; inspect grounding; bonding; and isolation

3-10

DPC-fault

Check DPC status indicator for specific problem

3-11

DPC valve control fault

Check DPC status indicator for specific problem

3-12

DMC fault

Check DMC status indicator for specific problem

3-13

Gas Controller not Con-

figured.

DMC and / or DPC not configured for a process or locked. Load process from TSC 3000 or

CNC. Check DMC & DPC status.