INSTALLATION

3-24

Manual No. 0-5163

ULTRA-CUT 400

Attach and tighten all #6 JIC fittings with 11/16” (18mm) wrench. Do not overtighten as it will strip the fitting threads

and will cause a leak. Do not start the Ultracut without coolant in the reservoir. An additional gallon (3.78l) of

coolant is required to compensate for the HE400 being attached to the system. Monitor the fluid level while filling

the UltraCut. Do not allow the coolant reservoir level to drop below minimum.

Attach the J71 cable after the Cooler and coolant lines have been determined to be leak free.

J71

To Ultra-Cut

Return

Supply

To Arc Starter

Return

Supply

Art # A-09624

Under low power plasma cutting the HE400 may not come on. This is normal operation.

Periodically check obstructions in the radiator and remove them by vacuuming the fins. Do not use cleaners or

fluids to remove debris, they may affect the radiator integrity.