3-37 INSTALLATION

ULTRA-CUT 400

3.19 Install TSC-3000 Touch Screen Control

Mounting Dimensions

6.99 in

[177.5 mm]

TSC-3000 Profile

5.58 in

[141.7 mm]

2.35 in

[59.69 mm]

1.11 in

[28.2 mm]

12.45 in

[316.2 mm]

.25 in

[6.35 mm]

11.80 in

[299.7 mm]

10.83 in

[275.0 mm]

TSC-3000 Top

Art # A-09156

Preparation

1. Select a clean, dry location with good ventilation and adequate working space around all components. Review

the safety precautions in the front of this manual to be sure that the location meets all safety requirements.

The TSC-3000 mounting brackets allow for mounting on or under a horizontal surface as well as left or right

of a vertical surface. Choose which ever works best for protection against moving equipment and flying

metal/cutting debris etc..

2. Once the unit has been secured to a flat surface, attach Communication cable (“V” which is already attached

to the CCM done in sub section 3.10) and ground cable (“F”) to the rear of the unit.

Communication Cable to/from
CCM rear of power supply

Ground Cable to/from
“Star” ground on table

Art # A-09157_AB