Ultra-cut 400 – Tweco 400 Ultra-Cut(March 2013) User Manual

Page 44

Advertising
background image

INSTALLATION

3-18

Manual No. 0-5163

ULTRA-CUT 400

3.11 Connect TSC-3000 Cable and DMC-3000 Fiber Optic Cable to CCM

1. Remove the plastic plug in the CCM at the rear of the Power Supply labelled GCM/DCM.

RETURN

SUPPLY

Art # A-09455

To TSC-3000

Fiber Optic

To DMC-3000

CAUTION

Avoid kinking, twisting, or bunching the fiber optic cable. The cable can be damaged by being forced into
tight-radius turns.

2. Remove outer thin nut from through hole protector at one end of Fiber Optic Cable (L) that connects between

the CCM portion of the Power Supply and the DMC-3000.

3. Feed the Fiber Optic Cable plug and wires through the hole where the plastic plug was removed labelled

GCM/DCM and slide the thin nut back over the Fiber Optic Cable.

4. Secure the thin nut on the through hole protector so both nut faces are tight against the sheet metal inside

and out.

5. Plug the Fiber Optic Cable into the PCB as shown below. Make sure the locking tabs are engaged. Fiber

Optic for the DMC-3000 goes into the lower pair of fiber optic receptacles (U10 & U13).

Advertising