Ultra-cut 400, Thermal dynamics, Ccm module – Tweco 400 Ultra-Cut(March 2013) User Manual

Page 159: I/o pcb cpu pcb

Advertising
background image

Manual 0-5163

A-19 APPENDIX

ULTRA-CUT 400

Art # A-09527

Art # A-09527

1

1

2

2

3

3

4

4

5

5

6

6

7

7

8

8

9

9

10

10

A

A

B

B

C

C

D

D

E

E

F

F

/PUMP

+15

V

+15V

460

/FAN
/RAS

COM

230

24VA

C

460

24 VAC RE

T

+15V

/ AC

/ TEMP

/ STATUS

/ DC

/ GAS - COOLANT

COM

POT WIPER (GCM1000)

POT LOW (GCM 1000)

AC230V @ 5A

230

PLASMA ENABLE

PRESS OK (GCM 1000)

+15

V

PLASMA ENABLE

POT HI (GCM1000)

460

AC120V @ 1A

AC13V @ 2A

230

- ARC V

- ARC V

AC120V-RAS

0V-RAS (120V ret)

0V-A (24V ret)

NEG ARC VOLTS

To PCB7 TB

3

0V-RAS

AC120V-RAS

AC230V RET

NEG ARC VOLT

S

DC 15V

AC24V-GCM

DC 0V

AC230V @ 1.25A

AC230V RET

AC230V @ 1.25A

PILOT (TIP) VOLT

S

0V-B (120V ret)

WORK

AC24V-GCM

DC 15V

DC 0V

AC120V-GCM

To T1 PRI -

0

AC24V-GCM

0V-A (24V ret)

AC120V-GCM

0V-B (120V ret)

0V-A (24V ret)

WORK

To PCB7 CN2-1

AC120V-GCM

0V-B (120V ret)

To PCB7 CN2-2

DWG No:

Sheet

of

Supersedes

Scale

Date:

Drawn:

References

Date

By

Revisions

Rev

PCB No:

Assy No:

Information Proprietary to THERMAL DYNAMICS CORPORATION.

Not For Release, Reproduction, or Distribution without Written Consent.

NOTE: UNLESS OTHERWISE SPECIFIED -

1. RESISTOR VALUES ARE EXPRESSED IN OHMS, 1/4W 5%.

2. CAPACITOR VALUES ARE EXPRESSED IN MICROFARADS (uF).

Chk: App:

TITLE:

Last Modified:

Size

SCHEMATIC,

Thermal

Dynamics

AA

42X1336

Monday, April 19, 2010

2

2

Industrial Park #2

West Lebanon NH 03784

603-298-5711

400-Amp Power Supply 208-230 / 460V

08:11:44

Thermal Dynamics

D

DWG No:

Sheet

of

Supersedes

Scale

Date:

Drawn:

References

Date

By

Revisions

Rev

PCB No:

Assy No:

Information Proprietary to THERMAL DYNAMICS CORPORATION.

Not For Release, Reproduction, or Distribution without Written Consent.

NOTE: UNLESS OTHERWISE SPECIFIED -

1. RESISTOR VALUES ARE EXPRESSED IN OHMS, 1/4W 5%.

2. CAPACITOR VALUES ARE EXPRESSED IN MICROFARADS (uF).

Chk: App:

TITLE:

Last Modified:

Size

SCHEMATIC,

Thermal

Dynamics

AA

42X1336

Monday, April 19, 2010

2

2

Industrial Park #2

West Lebanon NH 03784

603-298-5711

400-Amp Power Supply 208-230 / 460V

08:11:44

Thermal Dynamics

D

DWG No:

Sheet

of

Supersedes

Scale

Date:

Drawn:

References

Date

By

Revisions

Rev

PCB No:

Assy No:

Information Proprietary to THERMAL DYNAMICS CORPORATION.

Not For Release, Reproduction, or Distribution without Written Consent.

NOTE: UNLESS OTHERWISE SPECIFIED -

1. RESISTOR VALUES ARE EXPRESSED IN OHMS, 1/4W 5%.

2. CAPACITOR VALUES ARE EXPRESSED IN MICROFARADS (uF).

Chk: App:

TITLE:

Last Modified:

Size

SCHEMATIC,

Thermal

Dynamics

AA

42X1336

Monday, April 19, 2010

2

2

Industrial Park #2

West Lebanon NH 03784

603-298-5711

400-Amp Power Supply 208-230 / 460V

08:11:44

Thermal Dynamics

D

-15VDC_ISO

RS 485 (2 wire)

uses Tx+ & Tx- only

(used for TSC 3000)

RIBBON CABLE

TEST SOCKET

(F1 Sht 1)

RS 422 (4 wire)

connect TX+ to RX+

of CNC, Tx- to Rx-

of CNC

(F1 Sht 1)

ISOLATED

VOLTAGES

DCS1

100VAC - 24 VDC

JUMPER IN

REMOTE

HMI

** RS 485 / 422

on CPU board

19X2554 only.

NEG ARC VOLTS

SW6 - OK to MOVE CONTACTS / VOLTS

SW11 - ANALOG CURRENT SELECT

"B" DEFAULT, "A" REMOTE

KEY PLUG

Was 7 pin

changed to

14 pin in 2009

SW12 - DIVIDED ARC V RATIO SELECT
SW13 - FACTORY ONLY

PCB7 WK-5628

RELAY PCB

CIRCUIT COMM (GND)

CN11 34 CKT

CN10 26 CKT

PCB 5 WK-6276A (partial) INTERFACE PCB

PILOT DEM to PS

ANALOG DEM to CPU

Iso

J36 34 CKT

Wednesday, February 10, 2010

PCB6 DISPLAY

WK-5603

JUMPER

for 2 WIRE

(RS485 only)

wire to A & B

4W

4W

2W

JUMPER

for 4 WIRE

uses

TX+, TX-

RX+, RX-

J35 26 CKT

J14

J14

2W

SW14

SW14 - LINE

TERMINATION

normally on

(refer to manual)

CUT DEM to PS

RIBBON CABLE

5

9

8

76

1

2

3

4

SW10-ADDRESS

normally 0

(refer to

manual)

0

TEST SOCKET

UNDIVIDED ARC VOLTS

FOR HEIGHT CONTROLS

GND

GND

& CNC COMM

PLASMA ENABLE

24 VAC @ 1A

120 VAC @ 100ma.

(Not in all units)

POWER SUPPLY

REAR PANEL

TO AC

INDICATO

R

(on PCB6

)

29-41 VDC

RIBBON CABLE SIGNALS

/ = active low digital signal
CN10-J35 - 26 Ckt Ribbon Cable
2- Cut Demand

4- Pilot Demand

6- / Start

7- / Start2

9- / Pilot Enable

10- / HF Enable

12- / Pump Enable

13- / Fan Enable

15- / DC Indicator

16- / Over Temperature Indicator

18- / Gas-Coolant OK Indicator

19- / Status Lamp
CN11-J36 - 34 Ckt Ribbon Cable
1- Output Current Signal

3- / Arc Transferred (CSR)

4- / Pilot On

6- Coolant Flow (freq)

7- Coolant Temp (analog)

9- / Temp OK (Inverter/Chopper)

10- / Coolant Level OK

12- Missing Phase

13- / Ready to Operate

15- / Input Volts OK

16- / Inverter OCR

18- / PS ID "00*"

19- / PS ID "0*0"

20- / PS ID "*00"

21- E-Stop

22- E-Stop

29,31,33- 24 VAC Supply

30,32,34- 24 VAC Return

START / STOP

DIVIDED ARC VOLTS

Rx-
Tx+
Rx+
Tx-

REMOTE ANALOG

CURRENT CONTROL

+15VDC

+5VDC

-15VDC

COOLANT FLOW (freq) *

OK TO MOVE

I/O PCB

CPU PCB

DAT

230 VAC @ 1.25A

for Ext Heat

Exchanger

OK to MOVE -

E-STOP -

E-STOP +

* REMOTE MARKING +

OK to MOVE +

MOMENTARY START / STOP

START / STOP

* REMOTE MARKING -

STOP

START

(F1 Sht 1)

(F1 Sht 1)

MC2=PILOT

CONTACTOR

INPUT

CONTACTORS

TB1

TB2

+

-

Signal - Basic ID

Used to identify

GCM 1000 present

DIVIDED ARC V +

DIVIDED ARC V -

REMOTE ANALOG CURRENT CONTROL -

REMOTE ANALOG CURRENT CONTROL +

PILOT (TIP) VOLTAGE

TB3

COOLANT TEMP

(ON COOLANT

RETURN)

PILOT ON

OUTPUT

* OK2

* Only in CCM w/19X2634 I/O PCB.

Remote Marking only for DFC 3000

(not isolated).

SW8-4 on CPU PCB must be on to

enable Remote Marking.

ISOLATED COMM

+16 to +18VDC

* OK2

HOLD START -

HOLD START +

* +10VDC @ 10 ma.(for CC pot high)

Rx-

Tx+

Rx+

Tx-

PREFLOW ON -

CCM MODULE

PREFLOW ON +

Signal & GND

Isolated from

Plasma Supply

INTERNAL TERMINAL

STRIP TB3

KEY PLUG

+15VDC_ISO

ECO-B1507 - Initial Release

4-16-2010

DAT

To J70 (at C9) for

Ext. Heat Exchanger

(HE400) Power

To J59

(Grid C9)

To J55

(Grid E9)

To J55 & TB3

(grids D9, A10)

To J55 & TB3

(grids D9, A10)

From T1

(Grid D2)

From T2

(Grid F3)

From T1 (Grid D2)

From CN7

(Grid E4)

From CN12 (Grid E4)

From

(Grid C9, sht 1)

From

(Grid A9, sht 1)

From

(Grid

D2)

From Sheet 1

Grids (A9, B9 & C9)

1

2

J1

J1

1

2

3

4

5

6

7

8

9

YELLOW

TEMP

YELLOW

TEMP

1

2

3

CN1

CN1

1

2

3

4

5

6

44

E-STOP

E-STOP

CN6

CN6

1

2

3

4

GAS ON

GAS ON

TP11

TP11

J6 **

J6 **

1

2

3

4

5

6

33

1

2

TP12

TP12

CN3

CN3

4

5

TB1

TB1

66

MC3

MC3

CN1

CN1

1

2

J15-CNC

J15-CNC

1

2

3

4

5

6

7

8

9

10

11

12

13

14

R7

1K 30W

R7

1K 30W

88

11

11

TP2

TP2

TB4

TB4

D28

CNC_PREFLOW

D28

CNC_PREFLOW

TP9

TP9

J9

J9

1

2

3

4

5

6

99

D17

RS485 TXD

D17

RS485 TXD

100K3

100K3

PUMP

MOT1

PUMP

MOT1

'

.

11

CN5

CN5

1

2

3

4

5

6

55

77

+V

GN

D

SI

G

FL1

FLOW_TURBINE_PULSE

+V

GN

D

SI

G

FL1

FLOW_TURBINE_PULSE

R

B

G

T2

T2

600_

460_

0...

230

400__

220__

200__

0___

11

1

2

3

CN7

CN7

1

2

3

4

RED

STATUS

RED

STATUS

RY1-1

RY1-1

D15

PSR

D15

PSR

88

CN14

CN14

1

2

RY3

RY3

MC1

MC1

MC5 AU

X

MC5 AU

X

TP4

TP4

22

1

2

1

2

CN12

CN12

1

2

MC4

MC4

LSW1-1

SW_LIQUID_LEVEL_NC

LSW1-1

SW_LIQUID_LEVEL_NC

TP1

TP1

C.P8

C.P8

1

2

12

12

J4

J4

1

3

5

7

TP15

TP15

T1

T1

460

220

0,

13

0,,

100

0.

200

0..

110

0...

120.

0_

24.

0__

24_

0___

120.

0___

TP17

TP17

D18

RS485 RXD

D18

RS485 RXD

D2&3

CANBUS ACTIVE

D2&3

CANBUS ACTIVE

J55-GCM

J55-GCM

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

19

20

21

22

23

24

25

26

27

28

29

30

31

32

33

34

35

36

37

66

33

TP5

TP5

1

2

3

J54-REMOTE HMI

J54-REMOTE HMI

1

2

3

4

5

6

7

8

9

10

11

12

13

14

OK2 *

OK2 *

RY4

RY4

GREEN

AC

GREEN

AC

CN13

CN13

1

2

3

88

CN9

CN9

1

2

3

FAN1

FAN1

+

-

MC6

MC6

10

10

22

CN8

CN8

1

2

3

4

99

44

RY4

RY4

C.P4

C.P4

C.P6

C.P6

TP16

TP16

D12

STATUS CODE

D12

STATUS CODE

TP18

TP18

22

77

CN29

CN29

1

2

3

4

5

GREEN1

GAS

GREEN1

GAS

MC3 AU

X

MC3 AU

X

CN11

CN11

1

2

66

11

11

44

TP14

TP14

CN2

CN2

1

2

C.P2

C.P2

D23

CNC_START

D23

CNC_START

1K

1K

TP7

TP7

CN12

CN12

1

2

3

J5

J5

1

2

3

4

5

J59-RAS

J59-RAS

1

2

3

4

5

6

7

8

9

10

11

12

13

14

J6

J6

1

5

8

PSR

PSR

RY1

RY1

CN11

CN11

1

2

3

K6-2

K6-2

C.P3

C.P3

11

MC4 AU

X

MC4 AU

X

12

12

t

TH1

t

TH1

10

10

CN5

CN5

1

2

3

4

5

6

CN4

CN4

1

2

3

1

2

TP6

TP6

+

RY1

+

RY1

33

TP13

TP13

11

11

MC2

MC2

D21

CNC_E-STOP

D21

CNC_E-STOP

CN3

CN3

1

2

3

C.P7

C.P7

TP8

TP8

TP10

TP10

TB2

TB2

D9

GAS_ON

D9

GAS_ON

TP3

TP3

10

10

D8

OK_CNC

D8

OK_CNC

J8

J8

1

2

3

4

CN1

CN1

1

3

J70 - HE

J70 - HE

7

2

3

1

2

3

22

K7

K7

CN8

CN8

1

2

3

4

55

GREEN2

DC

GREEN2

DC

D13

+5V

D13

+5V

MC5

MC5

RY3

RY3

99

RY5

RY5

D26

HOLD_START

D26

HOLD_START

11

J7

J7

1

2

3

4

5

6

7

8

9

+

RY2

+

RY2

55

RY5

RY5

TB3

TB3

TB5

TB5

100K

100K

C.P5

C.P5

CN9

CN9

1

2

3

4

5

77

FAN2

FAN2

+

-

D7

E-STOP_PS

D7

E-STOP_PS

MC1 AU

X

MC1 AU

X

12

12

D11

INITIALIZING / PROGRAMMING

D11

INITIALIZING / PROGRAMMING

Advertising