4.12 DMC-3000 Status Codes

Status Code indicators:

1. At power up, RED & GREEN indicators flash program firmware revision number in a 2 digit code as ex-

plained below. Following the revision code

2. Green indicator

· On steady = OK, communication established.
· Blinking = no communication established with CCM
3. Red indicator

· Off = Status OK
· Rapid blinking = downloading new program
· Blinking 2 digit code = Status (table below)

Status Indicators on the DMC & DPC modules flash a 2-part code. Both green and red flash the firmware version

at power up. Only the red flashes for a fault.

First part of the code indicates a code group, the second part a particular condition within that group. DMC and

DPM may flash codes at the same time and they may be different codes. For example, a power supply fault, such as

1-3, in the DMC could prevent communicating with the DPM so the DPC would flash one it’s group 2 codes. You

have to consider the codes in all the modules, CCM, DMC & DPC before determining which hardware has the fault.

The 2 digit code is separated by a 1.2 second space between digits and a 4 second space before the sequence repeats

or flashes another code group. Codes displayed may be currently active or may represent a fault that shut the

process down but is no longer active. If the fault that shut down the process is no longer active the first blink of

the first digit is extra long.

Example: Indicator flashes 1 long followed by 3 shorter blinks the condition is in group 4. After 1.2 seconds delay,

the indicator blinks 3 times; the condition code is 4-3 (the first long blink counts as part of the first digit), indicat-

ing the DMC has detected a DPC time-out error and it is not currently active. After a 4 second delay, the indicator

repeats the sequence until the condition is corrected.

DMC Status Code Key

Code

Message

Cause/Remedy

Group 1 - DMC

1-1

Plasma Disabled

Enable Plasma; Defective DMC Power Supply (E-Stop relay)

1-2

24 VDC fault

Check /replace DMC power supply fuse (F2); Replace DMC Power Supply; Replace DMC

control PCB

1-3

5 VDC fault

Check /replace DMC power supply; Replace DMC control PCB

1-4

No gas process selected

Select and send process from TSC 3000 or CNC;

1-5

DMC is locked

Process loading, wait until finished

1-6

Gas not Purged

DPC fault prevented purge from occuring, see DPC fault status

Group 2 - DPC Communication Port *

2-1

DPC Acknowledge error

Check DMC to DPC fiber optic cable and connections; Dirty or defective fiber-optic;DPC

power supply, fuse or Control PCB. DMC Control PCB

2-2

DPC Bus off error

Check DMC to DPC fiber optic cable and connections; Dirty or defective fiber-optic;DPC

power supply, fuse or Control PCB. DMC Control PCB.

2-3

Reserved

No information available; Contact customer service