Cooling fans, Removing a cooling fan – Dell PowerEdge R910 User Manual

Page 115

Advertising
background image

Installing System Components

115

Cooling Fans

Your system contains six single-rotor hot-swappable fans to provide cooling

for the processors, expansion cards, and memory modules.

NOTE:

In the event of a problem with a particular fan, the fan number is referenced

by the system’s management software, allowing you to easily identify and replace

the proper fan by noting the fan numbers on the fan assembly.

Removing a Cooling Fan

WARNING:

The cooling fan can continue to spin for some time after it has been

powered down. Allow time for the fan to stop spinning before removing it from
the system.

WARNING:

Do not attempt to operate the system without the cooling fans or

the cover.

CAUTION:

Many repairs may only be done by a certified service technician.

You should only perform troubleshooting and simple repairs as authorized in
your product documentation, or as directed by the online or telephone service
and support team. Damage due to servicing that is not authorized by Dell is not
covered by your warranty. Read and follow the safety instructions that came
with the product.

NOTE:

The procedure for removing each individual fan module is the same.

1 Open the system. See "Opening the System" on page 89.
2 Press the release tabs toward each other and lift the fan out of the fan

assembly. See Figure 3-15.